Product Description
|
Specifications
|
||
|---|---|---|
| Model | Salicru 662AG000011 Line Interactive 1100VA UPS | |
| Technology | Line-interactive | |
| Format | Convertible tower/rack (2U) | |
| INPUT | ||
| Rated Voltage | 208 V / 220 V / 230 V / 240 V | |
| Voltage Range (100% load) | 170 V ÷ 280 V | |
| Stabilizer | AVR (Buck & Boost) | |
| Rated Frequency | 50 / 60 Hz (auto-detection) | |
| Frequency Range | ±5 Hz | |
| Auto Detection of Frequency | Yes | |
| Protection | Fuse (800/1100) or resettable thermal cutoff (1500/2000/3000) | |
| OUTPUT | ||
| Power Factor | 0.9 | |
| Rated Voltage | 208 V / 220 V / 230 V / 240 V | |
| Voltage Accuracy (Battery Mode) | ±1.5% | |
| Power (VA/W) | 1100 VA / 990 W | |
| Total Harmonic Distortion (THDv) | < 2% (linear load) / < 5% (non-linear load) | |
| Waveform (Battery Mode) | Pure sine wave | |
| Frequency | 50 / 60 Hz (same as input) | |
| Frequency Accuracy (Battery Mode) | ±0.1 Hz | |
| Admissible Overloads in Battery Mode | < 120% off at 1 min / < 150% off at 10 s | |
| Admissible Overloads in Line Mode | < 120% off at 5 min / < 150% off at 10 s / >150 %: 1 s | |
| Socket Type | IEC | |
| No. of Sockets | 8 | |
| Programmable Sockets | Yes, for critical / non-critical loads (4/4) | |
| BATTERY | ||
| Battery Type | Pb-Ca sealed, AGM, maintenance-free | |
| Charge Type | I/U (constant current/constant voltage) | |
| Recharge Time | 4 hours to 90% | |
| Battery Test | Automatic on every start + one time per week | |
| CHARGER | ||
| Temperature Voltage Compensation | Yes | |
| COMMUNICATION | ||
| Ports | RS-232 / USB-HID | |
| Intelligent Slot | Slot for SNMP/potential-free contacts/ MODBUS | |
| Monitoring Software | Compatible with Windows, Linux, and Mac | |
| INDICATIONS | ||
| Type | LCD + keypad | |
| Display Values | Voltage, power and input/output frequency, battery voltage, % battery charge, % load, operating mode, fault, discharge time, mute | |
| Operating Modes | Normal / Stabilisation (AVR) / Battery / Fault | |
| Alarm | Output battery mode, polarity, low battery, charger failure, overload | |
| Audible Alarm | Every 10 s for battery operation. Every 2 s for low battery / Polarity. Every 1 s for overcharge. Continuous for fault. | |
| Failure Display | LCD | |
| OTHER FUNCTIONS | ||
| Cold Start | Yes | |
| Emergency Stop (EPO) | Yes | |
| ADSL/Fax/Modem Transient Protector | Yes | |
| Green Function | Yes, automatic stop in battery mode with load <5% | |
| Smart Fan Speed | Yes, smart control of fan speed | |
| Site Wiring Fault | Yes, error detection of phase-neutral rotation and/or absence of earth | |
| GENERAL | ||
| Operating Temperature | 0ºC to +40ºC | |
| Relative Humidity | Up to 95%, non-condensing | |
| Maximum Operating Altitude | 2400 meters above sea level (power degradation up to 5,000 m) | |
| Acoustic Noise at 1 Meter | < 45 dB | |
| STANDARDS | ||
| Safety | EN IEC 62040-1 | |
| Electromagnetic Compatibility (EMC) | EN IEC 62040-2 (C2) | |
| Operation | EN IEC 62040-3 | |
| Corporate Certification | ISO 9001, ISO 14001, ISO 45001 | |
| DIMENSIONS | ||
| Depth (mm) | 410 mm | |
| Width (mm) | 438 mm | |
| Height (mm) | 88 mm | |
| WEIGHT | ||
| Weight (kg) | 13.4 kg | |
General Inquiries