Belden 10GX24 07305 Category 6A Non-Bonded-Pair UTP LSZH Cable Price in Dubai UAE

Belden 10GX24 07305 Category 6A Non-Bonded-Pair UTP LSZH Cable Price in Dubai UAE

Sold: 0

10GX Category 6A Enhanced Premise Horizontal Cable (625MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Haloarrest® LSZH Jacket

Enquire on Whatsapp
SKU: 10GX24 07305 Category:

Product Description

Product Overview
Suitable Applications Premise Horizontal Cable, Ethernet up to 10GBASE-T, HDBaseT, PoE++, PoE+, PoE
Patent This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.
Construction Details
CONDUCTOR
Size Stranding Material Number of Pairs
23 AWG Solid BC – Bare Copper 4
INSULATION
Material Color Code
PO – Polyolefin White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
OUTER JACKET
Separator Material Material Trade Name Nom. Diameter Ripcord
Double H Cross-Web (Patented RoundFlex®) LSZH – Low Smoke Zero Halogen (Flame Retardant) Haloarrest® 0.295 in (7.49 mm) Yes
Overall Cable Diameter (Nominal) 0.295 in (7.49 mm)
Electrical Characteristics
ELECTRICALS
Max. Conductor DCR Max. Capacitance Unbalance
74 Ohm/km (23 Ohm/1000ft) 90 pF/100m
DELAY
Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
100 MHz 537.6 ns/100m 45 ns/100m 64%
HIGH FREQUENCY
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. PSACR [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) [Ohm] Max./Min. Fitted Impedance [Ohm] Min. PSANEXT [dB] Min. PSAACRF [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.1 dB/100m 73.3 71.2 68.8 20.0 100 ± 15 100 ± 15 67.0 67.0 40.0 35.0
4 3.8 dB/100m 64.3 60.5 56.8 23.0 100 ± 15 100 ± 10 67.0 67.0 40.0 23.0
8 5.3 dB/100m 59.8 54.4 50.7 24.5 100 ± 15 100 ± 10 67.0 61.1 40.0 16.9
10 5.9 dB/100m 58.3 52.4 48.8 25.0 100 ± 15 100 ± 10 67.0 59.2 40.0 15.0
16 7.5 dB/100m 55.2 47.8 44.7 25.0 100 ± 15 100 ± 10 67.0 55.1 40.0 10.9
20 8.4 dB/100m 53.8 45.4 42.8 25.0 100 ± 15 100 ± 10 67.0 53.2 38.0 9.0
25 9.4 dB/100m 52.3 43.0 40.8 24.3 100 ± 15 100 ± 10 67.0 51.2 36.0 7.0
31.25 10.5 dB/100m 50.9 40.4 38.9 23.6 100 ± 15 100 ± 10 67.0 49.3 35.1
62.5 15.0 dB/100m 46.4 31.4 32.9 21.5 100 ± 15 100 ± 10 66.6 43.3 32.0
100 19.1 dB/100m 43.3 24.2 28.8 20.1 100 ± 15 100 ± 10 63.5 39.2 30.0
200 27.6 dB/100m 38.8 11.2 22.8 18.0 100 ± 22 100 ± 10 59.0 33.2 27.0
250 31.1 dB/100m 37.3 6.3 20.8 17.3 100 ± 32 100 ± 10 57.5 31.2 26.0
300 34.3 dB/100m 36.1 1.9 19.3 16.8 100 ± 32 100 ± 10 56.3 29.7 25.2
350 37.2 dB/100m 35.1 17.9 16.3 100 ± 32 100 ± 10 55.3 28.3 24.6
400 40.1 dB/100m 34.3 16.8 15.9 100 ± 32 100 ± 10 54.5 27.2 24.0
450 42.7 dB/100m 33.5 15.7 15.5 100 ± 32 100 ± 10 53.7 26.1 23.5
500 45.3 dB/100m 32.8 14.8 15.2 100 ± 32 100 ± 10 53.0 25.2 23.0
550 47.7 dB/100m 32.2 14.0 14.9 100 ± 32 100 ± 10 52.4 24.4
600 50.1 dB/100m 31.6 13.2 14.7 100 ± 32 100 ± 10 51.8 23.6
625 51.2 dB/100m 31.4 12.9 14.5 100 ± 32 100 ± 10 51.6 23.3
750 56.7 dB/100m 30.2 11.3 14.0 50.4 21.7
860 61.2 dB/100m 29.3 10.1 13.6 49.5 20.5
VOLTAGE
UL Voltage Rating Voltage Rating
300 V RMS 300 V
Mechanical Characteristics
TEMPERATURE
Operating Installation Storage
-20°C To +75°C 0°C To +50°C -20°C To +75°C
BEND RADIUS
Stationary Min. Installation Min.
1.25 in (31.8 mm) 3.0 in (76 mm)
Max. Pull Tension 25 lbs (11 kg)
Bulk Cable Weight 34 lbs/1000ft
Standards and Compliance
Environmental Suitability LSZH, Indoor, Non-Halogenated
Sustainability Product Lens™, Environmental Product Declaration (EPD) Available
Flammability / Reaction to Fire IEC 60332-1-2
CPR Compliance CPR Euroclass: Eca
ICEA Compliance S-116-732-2013
IEEE Compliance IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA Compliance ANSI/NEMA WC-66
Data Category Category 6A
TIA/EIA Compliance ANSI/TIA-568.2-D Category 6A
ISO/IEC Compliance ISO/IEC 11801-1, IEC 61156-5
CENELEC Compliance Segregation class according EN50174-2 = a
European Directive Compliance EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance China RoHS II (GB/T 26572-2011)
Other Standard Compliance(s) Verified Channel/Category 6A
Plenum Number 10GX13
Non-Plenum Number 10GX12
Product Notes
Notes Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 625 MHz are for Engineering Information Only. 0.295″ Cable Dimension per TIA 6@1 Equivalent Diameter. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.

General Inquiries

There are no inquiries yet.

Back to top