APC Smart-UPS RT 6000VA, 230V, LCD, rackmount w/kit, 2x IEC 60320 C13 & 1x IEC 60320 C19 outlets SRTG6KXLI Price in Dubai UAE
Enquire on Whatsapp
Product Description
provided equipment |
Smart UPS signalling RS-232 cable
User manual |
|
---|---|---|
Number of tare power |
68 W
|
|
Number of power module free slots |
0
|
|
Number of power module filled slots |
0
|
|
redundant |
No
|
|
UPS size |
S
|
depth |
62 cm
|
|
---|---|---|
height |
17.78 cm
|
|
mounting preference |
No preference
|
|
net weight |
51.9 kg
|
|
mounting mode |
Rack-mounted with kit
|
|
two post mountable |
0
|
|
USB compatible |
No
|
|
width |
44 cm
|
network frequency |
40…70 Hz auto-sensing
|
|
---|---|---|
number of input connectors |
1 hard wire 3-wire (1P + N + E)
|
|
input voltage limits |
160…285 V
|
|
Input voltage |
220 V
240 V |
|
maximum input current |
30 A
|
|
switching current capacity |
40 A
|
|
input voltage |
230 V
|
rated power in W |
6000 W
|
|
---|---|---|
Maximum configurable power in W |
6000 W
|
|
harmonic distortion |
Less than 2 %
|
|
output frequency |
50/60 Hz +/- 3 Hz sync to mains
|
|
Output voltage |
220 V
240 V |
|
crest factor |
3 : 1
|
|
UPS type |
Double conversion online
|
|
Wave type |
Sine wave
|
|
output connector type |
Hard wire 3-wire (H N + E) 1
|
|
nb of power socket outlets |
2 IEC 60320 C13
1 IEC 60320 C19 |
|
bypass type |
Internal bypass (automatic and manual)
|
|
curve equation |
Efficiency
|
|
curve fixed loss |
0.0127
|
|
curve load maximum |
100 %
|
|
curve load minimum |
2 %
|
|
curve proportional loss |
0.0316
|
|
curve square loss |
0.020
|
|
curve X-axis maximum |
100 %
|
|
curve test cond ID |
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output.
|
|
curve X-axis minimum |
0 %
|
|
curve X-axis title |
Load
|
|
curve X-axis units |
Percentage
|
|
curve Y-axis maximum |
100 %
|
|
curve Y-axis minimum |
50 %
|
|
curve Y-axis title |
Efficiency
|
|
curve Y-axis units |
Percentage
|
|
full load runtime |
00:02:15 6000 W
|
|
graph display |
1
|
|
half load runtime |
00:08:30 3000 W
|
|
output voltage |
230 V
|
|
Maximum configurable power in VA |
6000 VA
|
|
rated power in VA |
6000 VA
|
product certifications |
CE
|
|
---|---|---|
standards |
EN/IEC 62040-1
|
ambient air temperature for operation |
0…40 °C
|
|
---|---|---|
relative humidity |
0…95 % non-condensing
|
|
operating altitude |
0…6600 ft
|
|
ambient air temperature for storage |
-15…45 °C
|
|
storage Relative Humidity |
Non-condensing 0…95 %
|
|
storage altitude |
0.00…15240.00 m
|
|
acoustic level |
55 dBA
|
|
heat dissipation |
1330.74 Btu/h
|
|
show note OP temperature |
No
|
|
IP degree of protection |
IP20
|
battery type |
Lead-acid battery
|
|
---|---|---|
number of battery filled slots |
2
|
|
number of battery free slots |
0
|
|
Battery recharge time |
4 h
|
|
additional information |
Configurable for 220 : 230 or 240 nominal output voltage
|
|
liquid value |
0
|
|
battery voltage |
+/- 96 V
|
|
battery curve |
C
|
|
battery charger power |
239 W rated
|
|
Battery power in VAH |
960 VAh capacity
960 VAh runtime |
|
battery life |
3…5 year(s)
|
|
battery option |
SRTG192XLBP4 1 2688 VAh
SRTG192XLBP4 2 4488 VAh SRTG192XLBP4 3 6461 VAh SRTG192XLBP4 4 8000 VAh |
|
extended runtime |
1
|
preinstalled device |
Network management card
|
|
---|---|---|
control panel |
LED Status display with on line : on battery
Multifunction LCD status and control console |
|
alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
|
|
Emergency power off |
Yes
|
Surge energy rate |
600 J
|
---|
Package 1 Weight |
59 kg
|
|
---|---|---|
Package 1 Height |
27.5 cm
|
|
Package 1 width |
59 cm
|
|
Package 1 Length |
79 cm
|
Warranty |
3 years repair or replace (excluding battery) and 2 years for battery
|
---|
General Inquiries
There are no inquiries yet.