APC Smart-UPS RT 5000VA, 230V, LCD, rackmount w/kit, 2x IEC 60320 C13 & 1x IEC 60320 C19 outlets SRTG5KXLI Price in Dubai UAE

APC Smart-UPS RT 5000VA, 230V, LCD, rackmount w/kit, 2x IEC 60320 C13 & 1x IEC 60320 C19 outlets SRTG5KXLI Price in Dubai UAE

Sold: 0

  • High density, double-conversion on-line power protection with scalable runtime

  • Includes: Smart UPS signalling RS-232 cable, USB cable, User manual

Enquire on Whatsapp
SKU: SRTG5KXLI Category:

Product Description

SRTG5KXLI Features

Key Features

Output power capacity

5.0kWatts / 5.0kVA
Output Connections

(1) Hard wire 3-wire (H N + E) (Battery Backup)
(2) IEC 60320 C13 (Battery Backup)
(1) IEC 60320 C19 (Battery Backup)
Nominal Output Voltage

230V
Nominal Input Voltage

230V
Input Connections

Hard wire 3-wire (1P + N + E)
APC Smart-UPS RT 5000VA, 230V, LCD, rackmount w/kit, 2x IEC 60320 C13 & 1x IEC 60320 C19 outlets
High density, double-conversion on-line power protection with scalable runtime
Includes: Smart UPS signalling RS-232 cable, USB cable, User manual
  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • LCD Status Display
    Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Smart-UPS On-Line Features & Benefits

Adaptability

Rack/Tower convertible

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Plug-and-Play external batteries

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash upgradeable firmware

Install maintenance releases of firmware remotely using FTP.

Availability

Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.
Scalable runtime

Allows additional run time to be quickly added as needed.
Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.

Manageability

Serial connectivity

Provides management of the UPS via a serial port.
Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
LED status indicators

Quickly understand unit and power status with visual indicators.
Intelligent Card Slot

Customize UPS capabilities with management cards.
InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.

Marketing features

Avoids costly power problems by keeping your IT equipment and data protected and available .

Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Save time with easy and convenient remote/network accessibility.

Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Peace of mind that comes with full equipment compatibility and reliability of a leader

Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Low operating and maintenance costs with proven reliability and intelligent battery management .

Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.

Protection

Cold-start capable

Provides temporary battery power when the utility power is out.
Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Serviceability

Predictive failure notification.

Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification

Warns when a battery is not available to provide backup power.
Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.
User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Audible alarms

Provides notification of changing utility power and UPS power conditions

Technical Specifications

Output

Max Configurable Power (Watts)

5.0kWatts / 5.0kVA
Output Voltage Note

Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion

Less than 2 %
Output Frequency (sync to mains)

50/60 Hz +/- 3 Hz Sync to mains
Other Output Voltages

220 V, 240 V
Load Crest Factor

3 : 1
Topology

Double conversion online
Waveform type

Sine wave
Bypass

Internal bypass (automatic and manual)

Input

Input frequency

40 – 70 Hz Auto-sensing
Input voltage range for main operations

160 – 285V
Other Input Voltages

220 V, 240 V

Batteries & Runtime

Battery type

Lead-acid battery
Included Battery Modules

2
Typical recharge time

4hour(s)
Nominal Battery Voltage

+/- 96 V
Expected Battery Life (years)

3 – 5
Battery Charge Power (Watts)

239 Watts
Extendable Run Time

1
Battery Volt-Amp-Hour Capacity

960

Communications & Management

Interface Port(s)

RJ-45 Serial, Smart-Slot, USB
Control panel

LED Status display with on line : on battery, Multifunction LCD status and control console
Audible Alarm

Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)

Yes

Surge Protection and Filtering

Surge energy rating

600Joules

Physical

Maximum Height

178MM, 17.78CM
Maximum Width

440MM, 44.0CM
Maximum Depth

620MM, 62.0CM
Net Weight

51.9KG
Shipping weight

59.0KG
Shipping Height

275MM, 27.5CM
Shipping Width

590MM, 59.0CM
Shipping Depth

790MM, 79.0CM

Environmental

Operating Temperature

0 – 40 °C
Operating Relative Humidity

0 – 95 (Non-condensing) %
Operating Elevation

0 – 2011.68meters
Storage Temperature

-15 – 45 °C
Storage Relative Humidity

0 – 95 (Non-condensing) %
Storage Elevation

0 – 15240meters
Audible noise at 1 meter from surface of unit

55.0dBA
Online thermal dissipation

1109.0BTU/hr
Protection Class

IP20

Conformance

Approvals

CE, EN/IEC 62040-1
Standard warranty

3 years repair or replace (excluding battery) and 2 years for battery

General Inquiries

There are no inquiries yet.

Back to top