Belden GUSN824 Universal OFC CLT (jelly filled): GLASS YARNS(1500N) + LSZH with 1 Tube of Ø3.3mm CPR Dca. 24f SM OS2 G.652.D & G.657.A1. Price in Dubai UAE

Belden GUSN824 Universal OFC CLT (jelly filled): GLASS YARNS(1500N) + LSZH with 1 Tube of Ø3.3mm CPR Dca. 24f SM OS2 G.652.D & G.657.A1. Price in Dubai UAE

Universal (Indoor/Outdoor) optical fiber Central Loose Tube (jelly filled tube) cable with glass yarns (standard rodent protection) as strength member and Low Smoke Zero Halogen outer jacket. Existing out of 1 Tube with a diameter of 3.3mm with CPR

SKU: Belden GUSN824 Category:

Product Description

Product Overview
Environmental Space Indoor/Outdoor – Euroclass Dca
Suitable Applications For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes.
Construction
FIBER CABLE CONSTRUCTION
Fiber Type Fiber Grade acc. ITU-T Fiber Count Subunit Color Subunit Color 2
OS2 G.652D & G.657A1 24 TIA coding (Gxxxxxx.T): Natural Europe coding (Gxxxxxx.0): Natural
Fiber Color Coding TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua. With Ringmark: BL, OR, GR, BR, GY, WT, RD, BK, YL, VT, PK, AQ
Fiber Color Coding 2 Europe coding (Gxxxxxx.0): Red, Natural, Yellow, Blue, Green, Violet, Brown, Black, Orange, Aqua, Pink, White. With Ringmark: RD, NA, YL, BL, GR, VT, BR, BK, OR, AQ, PK, WT
Cable Core Water Tight Yes
Cable Core Water Blocking Waterblocking Glass Yarns
Bulk Cable Weight 37 kg/km
SubUnit Specifications
Number of Active Subunits 1
Number of Subunit Positions 1
Fibers Per Subunit 24
Jacket Specifications
Number of Jackets Single Jacket
Type of Armor Non-Armored
Outer Jacket
OUTER JACKET MATERIAL
Material Nominal Diameter Ripcord
LSZH – Low Smoke Zero Halogen (Flame Retardant) 5.8 mm 0
Table Notes Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green
Optical Characteristics
Fiber Core Diameter 9 µm
Max Attenuation at 1310 nm 0.40 dB/km
Max Attenuation at 1550 nm 0.24 dB/km
Max Attenuation at 1625 nm 0.29 dB/km
Mechanical Characteristics
MECHANICAL TESTS
Description Tested Standard Requirement/Value According to Family Specification
Cable Min. Bend Radius Installation (Short Term) IEC 60794-1-21-E6 116 mm IEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term) IEC 60794-1-21-E11 58 mm IEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term) IEC 60794-1-21-E1 1500 N (337 lbf) IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term) IEC 60794-1-21-E1 500 N (112 lbf) IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term) IEC 60794-1-21-E3 15 kN/m IEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term) IEC 60794-1-21-E3 7.5 kN/m IEC 60794-3-10
Temperature Range
Operating Temp Range -30 °C to +70 °C
Installation Temp Range -5 °C to +50 °C
Storage Temp Range -30 °C to +70 °C
Product Material
UL Rating/Flame Test Non-UL Rated
Standards
IEC Flammability IEC 60332-1-2
IEC 60754-1 – Halogen Amount Zero
IEC 61034-2 – Smoke Density Min. Transmittance 60%
CPR Euroclass Dca-s2,d1,a1
REACH Compliant
ISO/IEC Compliance IEC 60794
UV/ Sunlight Protection yes
History
Update and Revision Revision Number: 0.79 Revision Date: 07-19-2021

Reviews

There are no reviews yet.

Be the first to review “Belden GUSN824 Universal OFC CLT (jelly filled): GLASS YARNS(1500N) + LSZH with 1 Tube of Ø3.3mm CPR Dca. 24f SM OS2 G.652.D & G.657.A1. Price in Dubai UAE”

Your email address will not be published. Required fields are marked *

General Inquiries

There are no inquiries yet.

Back to top