Belden OSP6U 0101000 Outside Premise Horizontal Gel-Filled Cat 6 1000 ft Cable Price in Dubai UAE

Belden OSP6U 0101000 Outside Premise Horizontal Gel-Filled Cat 6 1000 ft Cable Price in Dubai UAE

Sold: 0

Category 6 Premise Horizontal Cable (350MHz), OSP Rated, 4-Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Gel-Filled, Polyethylene Jacket

SKU: OSP6U 0101000 Category:

Product Description

Product Overview
Suitable Applications OSP-Outside, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Noisy Environments
Construction Details
CONDUCTOR
Size Stranding Material Number of Pairs
24 AWG Solid BC – Bare Copper 4
INSULATION
Material Color Code
PO – Polyolefin White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Waterblocking Gel Filled
OUTER JACKET
Separator Material Nom. Diameter Ripcord
Center Member (Patented X-Spline®) PE – Polyethylene 0.251 in (6.38 mm) Yes
Overall Cable Diameter (Nominal) 0.251 in (6.38 mm)
Electrical Characteristics
ELECTRICALS
Max. Conductor DCR Max. Capacitance Unbalance
93.8 Ohm/km (28.6 Ohm/1000ft) 160 pF/100m
DELAY
Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
100 MHz 537.6 ns/100m 45 ns/100m 65%
HIGH FREQUENCY
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) [Ohm] Max./Min. Fitted Impedance [Ohm] Min. TCL [dB] Min. ELTCTL [dB]
1 2.0 dB/100m 74.3 72.3 70.3 67.8 64.8 20.0 100 ± 15 100 ± 15 40.0 35.0
4 3.8 dB/100m 65.3 63.3 59.5 55.7 52.7 23.0 100 ± 15 100 ± 15 40.0 23.0
8 5.3 dB/100m 60.8 58.8 53.4 49.7 46.7 24.5 100 ± 15 100 ± 15 40.0 16.9
10 6.0 dB/100m 59.3 57.3 51.4 47.8 44.8 25.0 100 ± 15 100 ± 15 40.0 15.0
16 7.6 dB/100m 56.3 54.3 46.7 43.7 40.7 25.0 100 ± 15 100 ± 15 38.0 10.9
20 8.5 dB/100m 54.8 52.8 44.3 41.7 38.7 25.0 100 ± 15 100 ± 15 37.0 9.0
25 9.5 dB/100m 53.3 51.3 41.8 39.8 36.8 24.3 100 ± 15 100 ± 15 36.0 7.0
31.25 10.7 dB/100m 51.9 49.9 39.2 37.9 34.9 23.6 100 ± 15 100 ± 15 35.1 5.1
62.5 15.4 dB/100m 47.4 45.4 30.0 31.8 28.8 21.5 100 ± 15 100 ± 15 32.0
100 19.8 dB/100m 44.3 42.3 22.5 27.8 24.8 20.1 100 ± 15 100 ± 15 30.0
155 25.2 dB/100m 41.5 39.5 14.3 23.9 20.9 18.8 100 ± 22 100 ± 15 28.1
200 29.0 dB/100m 39.8 37.8 8.8 21.7 18.7 18.0 100 ± 22 100 ± 15 27.0
250 32.8 dB/100m 38.3 36.3 3.5 19.8 16.8 17.3 100 ± 32 100 ± 15 26.0
VOLTAGE
Voltage Rating
300 V
Mechanical Characteristics
TEMPERATURE
Operating Installation Storage
-40°C To +75°C -40°C To +60°C -40°C To +75°C
BEND RADIUS
Stationary Min. Installation Min.
1.0 in (25 mm) 2.5 in (64 mm)
Max. Pull Tension 25 lbs (11 kg)
Bulk Cable Weight 25 lbs/1000ft
Standards and Compliance
Environmental Suitability Outdoor, Outdoor, Sunlight Resistance, Aerial – When supported by messenger wire
Sustainability Product Lens™, Environmental Product Declaration (EPD) Available
ICEA Compliance S-116-732-2013, S-56-434, S-99-689, S-100-685
IEEE Compliance IEEE 802.3bt Type 1, Type 2, Type 3
NEMA Compliance ANSI/NEMA WC-66
Data Category Category 6
TIA/EIA Compliance ANSI/TIA-568.2-D Category 6
ISO/IEC Compliance ISO/IEC 11801-1, IEC 61156-5
CENELEC Compliance Segregation class according EN50174-2 = a
European Directive Compliance EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance China RoHS II (GB/T 26572-2011)
Product Notes
Notes Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for Use in Buildings in Wet Locations. Not Suitable for Direct Burial. Fully Water Blocked and Sunlight Resistant (Black Jacket Only). Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.