Belden GUSND06 1 Mtr Price in Dubai UAE.

Belden GUSND06 1 Mtr Price in Dubai UAE.

Sold: 0

د.إ 7.00

Universal (Indoor/Outdoor) optical fiber Central Loose Tube (jelly filled tube) cable with glass yarns (standard rodent protection) as strength member and Low Smoke Zero Halogen outer jacket. Product feature: This cable has standard rodent protection by glass yarns. Existing out of 1 Tube with a diameter of 3.3mm with 6 fibers MM OM3. CPR Euroclass Dca.

د.إ 7.00

Buy Now
Add to cart
SKU: Belden GUSND06 Category:

Product Description

Environmental Space Indoor/Outdoor – Euroclass Dca
Suitable Applications For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes.
Construction
FIBER CABLE CONSTRUCTION
Fiber Type Fiber Count Subunit Color
OM3 6 TIA coding (Gxxxxxx.T): Natural
Fiber Color Coding TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White
Cable Core Water Tight Yes
Cable Core Waterblocking Waterblocking Glass Yarns
Bulk Cable Weight 37 kg/km
SubUnit Specifications
Number of Active Subunits 1
Number of Subunit Positions 1
Fibers Per Subunit 6
Jacket Specifications
Number of Jackets Single Jacket
Type of Armor Non-Armored
Outer Jacket Specifications
OUTER JACKET
Material Nominal Diameter Nominal Wall Thickness Ripcord
LSZH – Low Smoke Zero Halogen (Flame Retardant) 5.8 mm 0.8 mm No
Table Notes Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green
Optical Characteristics
Max. Attenuation at 1300 nm 0.9 dB/km
Max. Attenuation at 850 nm 2.9 dB/km
Mechanical Characteristics
MECHANICAL TESTS
Description Tested Standard Requirement/Value According to Family Specification
Cable Min. Bend Radius Installation (Short Term) IEC 60794-1-21-E6 116 mm IEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term) IEC 60794-1-21-E11 58 mm IEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term) IEC 60794-1-21-E1 1500 N (337 lbf) IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term) IEC 60794-1-21-E1 500 N (112 lbf) IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term) IEC 60794-1-21-E3 15 kN/m IEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term) IEC 60794-1-21-E3 7.5 kN/m IEC 60794-3-10
Temperature Range
Operating Temperature Range -30 °C to +70 °C
Installation Temperature Range -5 °C to +50 °C
Storage Temperature Range -30 °C to +70 °C
Standards
UL Rating/Flame Test Non-UL Rated
IEC Flammability IEC 60332-1-2
IEC 60754-1 – Halogen Amount Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity 10 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH 4.3
IEC 61034-2 – Smoke Density Min. Transmittance 60%
CPR Euroclass Dca-s2,d1,a1
REACH Compliant
ISO/IEC Compliance IEC 60794
UV/ Sunlight Protection Yes

General Inquiries

There are no inquiries yet.

Back to top