Suitable Applications harsh environment, IIoT, factory or process automation, video, audio, data communication, etc.
Construction Details
CONDUCTOR
Element Number of Element Size Stranding Material
Pair(s) 1 22 AWG 7×30 TC – Tinned Copper
INSULATION
Element Material Nom. Thickness Nom. Insulation Diameter Color Code Notes
Pair(s) PE – Polyethylene (Foam) 0.029 in (0.74 mm) 0.087 in (2.2 mm) White/Blue Stripe & Blue/White Stripe HDPE
OUTER SHIELD
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 22 AWG (7×30) TC
Braid Tinned Copper (TC) 65%
OUTER JACKET
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.041 in (1.0 mm) 0.281 in (7.14 mm)
Table Notes Jacket OD +/- 0.006
Overall Cable Diameter (Nominal) 0.281 in (7.14 mm)
Electrical Characteristics
ELECTRICALS
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Pair(s) 18.2 Ohm/1000ft 11 pF/ft (36 pF/m) 20.9 pF/ft 120 Ohm 78% 6 Amps per Conductor at 30ºC
Conductor(s)
Nom. Outer Shield DCR 4.685 Ohm/1000ft (15.37 Ohm/km)
HIGH FREQUENCY (NOMINAL/TYPICAL)
Element Frequency [MHz] Nom. Insertion Loss (Attenuation)
Pair(s) 1 0.5 dB/100ft
VOLTAGE
UL Voltage Rating
300 V (CM, PLTC)
Mechanical Characteristics
TEMPERATURE
UL Temperature Operating
60°C -20°C to +60°C
BEND RADIUS
Stationary Min. Installation Min.
3.372 in (85.65 mm) 3.372 in (85.65 mm)
Max. Pull Tension 53.34 lbs (24.19 kg)
Bulk Cable Weight 43 lbs/1000ft
Standards and Compliance
Environmental Suitability Indoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to Fire UL 1685 UL Loading, FT1, IEC 60332-1-2
CPR Compliance CPR Euroclass: Eca
NEC / UL Compliance Article 725, Article 800, CM, PLTC
CEC / C(UL) Compliance CM
European Directive Compliance EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance China RoHS II (GB/T 26572-2011)
Product Notes
Notes Oil Resistance: Passes Oil Res II Per UL1277, Table 10.17. For CPE jacketed version order Part No. YR44345.